Developing reliable EV charging infrastructure is crucial for a sustainable future.

Background:
In compliance with IEC 62196-1 standards, the PE wire for DC charging cables must meet specific requirements, such as the temperature rise test or the short-time high current test.

For instance, consider a DC 400A CCS2 charging gun with a 35-square millimeter grounding wire. The grounding wire must endure a test current of 3100A for 6 seconds. The grounding circuit’s components should not exhibit cracks, breakage, or melting post-test, and the grounding continuity must remain intact for it to be deemed acceptable.

Scenario:
In a case involving a 250A, 1000VDC CCS2 charging cable fitted with a 25-square millimeter PE wire, subjecting the wire to a 2450A current for 6 seconds resulted in insulation melting and cracking.

Solutions:
– Opt for a cable with a higher temperature rating: Upgrading to a cable with insulation rated for higher temperatures enhances its capacity to withstand generated heat effectively.

– Enhance crimping quality: Inadequate crimping of the terminal can elevate contact resistance, leading to excessive heat at the connection point. Ensuring precise crimping methods and utilizing suitable crimping tools markedly diminishes overheating risks and enhances the overall reliability of the grounding connection.